Air or Liquid Cooled
Avtron manufacture both air and liquid cooled load banks for your commissioning projects.
Mise en réseau
Connecter et contrôler les bancs de charge sans fil au sein d'un réseau.
Capture des données
La capture de données et les rapports avancés fournissent des informations en temps réel sur les performances énergétiques.
Load Banks for Data Centers Brochure | Americas
Découvrir dès maintenantLoad Banks for Data Centers Brochure | Rest of World
Découvrir dès maintenantWhere are Load Banks used in Data Centers?
Load banks play a critical role in the commissioning, testing, and ongoing validation of data center infrastructure. As data centers increase in size, density, and complexity, controlled artificial loads allow operators to safely verify that power and cooling systems perform as designed—without risking live IT equipment.
Click the image below to see where load banks are used in data centers.
- S'assurer que l'alimentation de secours fonctionnera en cas de panne de courant.
- Mise en service et vérification de la puissance nominale
- L'entretien régulier des bancs de charge permet de maintenir le générateur dans un état de fonctionnement optimal.
- Les bancs de charge permettent d'identifier tout problème potentiel d'alimentation de secours susceptible d'entraîner des coupures de courant.
- Charger complètement les batteries pour simuler les conditions réelles et identifier les faiblesses potentielles.
- Valider le système électrique pour éviter les pannes coûteuses
- Méthode peu coûteuse de détermination de l'autonomie des batteries
- Tester et entretenir les onduleurs dans le cadre d'un programme de maintenance.
- Mettre en service les centrales de production d'électricité afin de garantir un fonctionnement correct dans des conditions réelles
- Assurer l'efficacité et la disponibilité de la distribution d'énergie
- Valider le comptage RPP
- Mettre en service les unités PDU afin de garantir leur bon fonctionnement dans des conditions réelles.
- Assurer l'efficacité et la disponibilité de la distribution d'énergie
- Valider le système de barres de bus de la PDU et surveiller les variations de température
- S'assurer que l'élévation de température des barres conductrices reste dans les limites avec des charges électriques spécifiques.
- Valider les prises de courant et les pistes d'alimentation
- Vérifier et valider l'efficacité de la distribution de l'énergie à tous les composants du serveur.
- Simuler la production de chaleur des serveurs pour vérifier les systèmes CVC des centres de données
- S'assurer que les conditions d'alimentation et de température du centre de données sont optimales avant d'installer des serveurs coûteux.
Types of Load Banks used in Data Centers
Portable Air Cooled Load Banks
Air-cooled load banks are commonly used to validate HVAC and airflow performance. By introducing a predictable heat load into the white space or mechanical areas, they allow operators to test cooling capacity, airflow distribution, redundancy, and control strategies under real-world conditions. This is especially important during commissioning, ensuring the facility can maintain environmental setpoints during peak demand.
Permanent Air Cooled Load Banks
For power system reliability, permanently installed load banks provide a dependable method for validating backup power systems over the life of the data center. Integrated into generator, UPS, or electrical infrastructure, they enable routine testing of emergency power capacity, load sharing, and system response without disrupting operations. Permanent load banks support compliance, reduce risk, and ensure critical power systems are always ready to perform when needed.
Bancs de charge refroidis par liquide
As liquid cooling becomes more prevalent, liquid-cooled load banks are increasingly used to test liquid cooling loops and associated auxiliaries. These load banks apply thermal load directly to the coolant, enabling validation of pumps, heat exchangers, CDU performance, control valves, and monitoring systems. Liquid-cooled testing allows operators to confirm flow rates, temperature differentials, alarms, and failover scenarios before connecting high-value IT equipment.
Comment les bancs de charge portables sont-ils utilisés pour les tests HVAC ?
Avec l'incroyable augmentation des besoins en données, les centres de données sont construits à un rythme record. Les bancs de charge sont un élément essentiel de la mise en service des systèmes de chauffage, de ventilation et de climatisation (CVC). Découvrez comment et pourquoi dans cette vidéo
Pourquoi les bancs de charge sont-ils si importants dans les applications des centres de données ?
Lire le livre blancDemander à être rappelé

Contacter le service commercial
Parlez à nos ingénieurs commerciaux experts de vos besoins en matière de bancs de charge.